Individual onsite wastewater planning

Size the load. Trace the assumptions. Test the site.

A transparent preliminary design workspace for septic tank capacity, conceptual geometry, soil absorption area and installation planning.

Calculation statusSite data neededEngine 1.9 · locally saved
Planning estimate only.Not a permit, structural tank design, soil certification or construction authorization. Local approval and qualified site evaluation are required.
Printable project recordCapture every input, output and hidden section

The full report expands all four diagrams, records inactive stored values and dropdown choices, includes all quote lines and sources, and prints the current checklist status. It may contain customer and pricing information.

Sample Data Lab

Load a complete source-based test case

Each sample populates every major input so you can test, modify and compare results before entering real project information.

Current project sampleNo sample loadedYour current project is unchanged.

Select a case to preview it. Your current project changes only after you click Load selected sample.

Selected caseNothing selected yet4 complete test cases available
One sample at a timeChoose a sample from the dropdown

Its public inputs, illustrative assumptions, expected result and source will appear here without changing your current project.

Public values and illustrative assumptions are separated for the selected sample. Exact trench layouts for the Washington cases come from the listed test geometry. Louisiana’s layout uses an illustrative percolation result with the state’s published line-length table. Replace every illustrative value and confirm all public values with the approving authority before real use.

01

Wastewater load

What defines the design flow?

Flow allowances and tank assumptions
Editable generic planning basisEPA guidance describes common residential code ranges, but it is not a universal code. Replace these values with the approving authority’s current rules.
02

Soil absorption

Verify the field design inputs

Site constraints and vertical separation
03

Installation planning

Set the physical constraints

Conceptual tank envelope
Not a structural tank designUse a listed, watertight tank and its approved dimensions, burial, traffic loading, anchoring, bedding and backfill instructions.
Detailed diagram callouts
Construction-coordination inputs onlyApproved exterior dimensions, wall and lid thickness, reinforcement, load rating, penetrations, partition openings, anchors, risers and seals must come from the selected tank submittal and approved plan.

These are editable planning values. Replace them with the approving authority, soil report, survey and selected product requirements before construction.

Approved tank product

Connections and baffles

Absorption-trench assembly

Authority setback placeholders

These are report placeholders—not universal requirements. Replace them with the values for the tank, field, wells and neighboring features in your jurisdiction.

Full site-plan sketch inputs
Rough rectangular planning envelopeThese dimensions drive a diagrammatic sketch only. Parcel bearings, easements, contours, utilities and final component coordinates require a survey and approved site plan.

Rough lot area: 37,500 ft². Enter a usable treatment area in the site section when known.

Calculation report

Transparent design basis

Generated when report printing begins.

A · Design flow

1,200 gal/day

8 bedrooms × allowance controls the current estimate.

Design population
12 people
Equivalent bedrooms
8
Occupancy route
900 gal/day
Bedroom route
1,200 gal/day
Show calculation

The selected load route is calculated once. Apartment mode compares occupancy and bedroom routes and uses the higher value; it does not add them.

Q = max(population × 75, bedrooms × 150)
B · Tank capacity

3,000 gal

Selected nominal capacity using hydraulic retention + solids storage.

Hydraulic storage
2,400 gal
Solids allowance
381 gal
Calculated minimum
2,781 gal
Nominal selected-volume retention
2.18 days
Show calculationV = Q × retention + people × solids allowance × pump interval

Then apply the entered minimum tank and round upward to the entered available size increment.

C · Soil absorption

Awaiting verified field basis

The tank estimate remains available while the dependent field result is suppressed.

Show calculationA = Q ÷ authority-accepted soil loading rate

Trench length = infiltrative bottom area ÷ credited trench width.

Shesons OnsiteFlow SOF · complete project record

Full detailed inputs and outputs

Generated when full-report printing begins.This appendix records values that may be collapsed, inactive or hidden in the interactive screen. Stored inactive alternatives are identified and do not control the current calculation.

Private project record · preliminary only.This report can contain customer contact details and pricing. It is not a permit, survey, structural design, excavation release or construction authorization.
Appendix A

Complete input register

Every stored project field, including inactive mode values and dropdown choices.

Project, provenance and selections

FieldRecorded valueUse / status
Project nameApartment wastewater conceptCurrent project value
Site / parcelNot enteredCurrent project value
Approving authorityNot enteredCurrent project value
Safety rule profileGeneric · user-entered rulesSelected profile; confirm the current local rules before real useAvailable choices: Generic · user-entered rulesKansas KDHE Bulletin 4-2Louisiana LDH · Title 51Washington WAC 246-272A
Prepared byNot enteredCurrent project value
Display unitsUS customaryCalculations are stored canonically in US units and converted for displayAvailable choices: US customaryMetric
Wastewater sizing basisApartmentsSelected design-flow routeAvailable choices: ApartmentsBedroomsPeopleDirect flow
Sample dropdown selectionNo sample selectedA preview selection does not change the project until it is loadedAvailable choices: Kansas · 4-bedroom homeLouisiana · 3-bedroom / 2-bath homeWashington · 3-bedroom homeWashington · 6 apartments
Loaded sample basisNo sample loadedCurrent project is not attached to a sample baseline
Screen diagram selectionSimpleThe full report prints all four views regardless of this screen selectionAvailable choices: SimpleDetailed measurementsFull site sketchConstruction blueprint

Wastewater load inputs — active and retained alternatives

FieldRecorded valueUse / status
Apartments4Active load route
Bedrooms per apartment2Active load route
Design people per apartment3Active load route
Total bedrooms3Stored inactive value — not used by the current load route
People6Stored inactive value — not used by the current load route
People per bedroom2Used to derive an equivalent bedroom/population value where applicable
Direct authority/design flow450 gal/dayStored inactive value — not used by the current load route
Flow allowance per person75 gal/dayUsed by the current load route
Flow allowance per bedroom150 gal/dayUsed by the current load route

Tank sizing inputs

FieldRecorded valueUse / status
Tank sizing methodHydraulic retention + solids storageSelected tank-capacity routeAvailable choices: Hydraulic retention + solids storageDaily-flow multiplierCapacity per bedroomAuthority-entered minimum
Daily-flow multiplierStored inactive value — not used by the current tank sizing route
Capacity per bedroom250 galStored inactive value — not used by the current tank sizing route
Hydraulic retention period2 daysActive tank sizing route
Solids allowance per person per year10.6 gal / person / yearActive tank sizing route
Pump interval3 yearsActive tank sizing route
Entered minimum tank1,000 galApplied to every tank sizing method
Nominal tank size increment250 galRequired capacity is rounded upward to this increment

Tank geometry, cover and approved product inputs

FieldRecorded valueUse / status
Conceptual liquid depth5 ftCurrent project value
Conceptual freeboard1 ftCurrent project value
Conceptual length-to-width ratio2.5:1Current project value
Entered tank cover1 ft 6 inManufacturer and structural rating control
Entered tank bedding depth6 inManufacturer and subgrade conditions control
Inlet-to-outlet drop2 inCurrent project value
Access opening diameter2 ftCurrent project value
Approved tank exterior length0 inNot entered — manufacturer hold
Approved tank exterior width0 inNot entered — manufacturer hold
Approved tank exterior height0 inNot entered — manufacturer hold

Soil and absorption-field sizing inputs

FieldRecorded valueUse / status
Field sizing methodDesign flow ÷ soil loading rateSelected absorption-field routeAvailable choices: Design flow ÷ soil loading rateAuthority field-line table per bedroom
Authority field line per bedroom0 inStored inactive value — not used by the current field sizing route
Authority minimum field line0 inStored inactive value — not used by the current field sizing route
Soil loading rate0.6 gal/day/ft²Active field sizing route
Soil / percolation basis verifiedNoDependent field calculations are held
Soil / percolation referenceNot enteredRecord the report, table row or approving-authority basis
Credited trench width3 ftCurrent project value
Maximum trench length100 ftCurrent project value
Clear spacing between trenches6 ftCurrent project value
Trench length rounding increment1 ftStored calculation input; included even when not exposed by the current screen controls
Replacement-area allowance100%Current project value
Entered usable treatment area0 ft²Not entered — area check is held

Site constraints and separation inputs

FieldRecorded valueUse / status
Trench-bottom depth2 ftCurrent project value
Seasonal high-water depth0 inUnknown
Restrictive-layer depth0 inUnknown
Required groundwater separation3 ftCurrent project value
Required restrictive-layer separation3 ftCurrent project value
Restrictive-layer rule is strictly greater thanNoPass allows ≥ entered separation
Entered site slope5%Current project value
Maximum permitted slope15%Current project value
Maximum-slope rule is strictly less thanNoPass allows ≤ entered maximum

Conveyance, pipe and fall inputs

FieldRecorded valueUse / status
Building-to-tank run50 ftCurrent project value
Tank-to-field run30 ftCurrent project value
Continuous-material allowance10%Current project value
Building sewer slope2%Current project value
Tank-to-field conveyance slope1%Current project value
Field lateral slope0.2%Current project value
Building sewer diameter4 inCurrent project value
Tank outlet / conveyance diameter4 inCurrent project value
Field lateral pipe diameter4 inCurrent project value

Tank internals and drainfield assembly inputs

FieldRecorded valueUse / status
Inlet baffle above liquid6 inCurrent project value
Inlet baffle below liquid6 inCurrent project value
Baffle vent clearance2 inCurrent project value
Outlet baffle above liquid6 inCurrent project value
Outlet baffle submergence40% of liquid depthCurrent project value
Serviceable effluent filter selectedYesCurrent project value
Primary compartment share66.67%Current project value
Aggregate below pipe6 inCurrent project value
Aggregate above pipe2 inCurrent project value
Minimum aggregate size0.5 inCurrent project value
Maximum aggregate size2.5 inCurrent project value
Crowned overfill height5 inCurrent project value

Rough site plan, setbacks and distribution inputs

FieldRecorded valueUse / status
Rough lot width150 ftCurrent project value
Rough lot depth250 ftCurrent project value
Rough building width50 ftCurrent project value
Rough building depth40 ftCurrent project value
Building setback placeholder5 ftCurrent project value
Well setback placeholder50 ftCurrent project value
Property-line setback placeholder5 ftCurrent project value
Surface-water setback placeholder50 ftCurrent project value
Distribution methodGravity distributionSelected distribution conceptAvailable choices: Gravity distributionPressure distribution
Timed dosing selectedNoStored inactive setting for gravity distribution
Appendix B

Complete calculated-output register

Held and unknown results remain explicit; they are not converted to zero.

Load calculation outputs

FieldRecorded valueUse / status
Design population12 peopleCurrent project value
Equivalent bedrooms8Current project value
Occupancy-route flow900 gal/dayCalculated route
Bedroom-route flow1,200 gal/dayCalculated route
Daily design flow1,200 gal/dayGoverning load used downstream
Controlling load basis8 bedrooms × allowanceCurrent project value
Overall calculation statusSite data neededCurrent project value

Tank sizing and conceptual geometry outputs

FieldRecorded valueUse / status
Hydraulic storage route2,400 galUsed by selected method
Solids storage route380.5 galUsed by selected method
Selected-method calculated capacity2,780.5 galhydraulic retention + solids storage
Tank method labelhydraulic retention + solids storageCurrent project value
Capacity after entered minimum2,780.5 galCurrent project value
Rounded nominal tank capacity3,000 galPlanning capacity only; approved product still required
Nominal selected-volume retention2.183 daysCurrent project value
Conceptual inside length14 ft 1.9 inGeometric planning model — not structural/product dimensions
Conceptual inside width5 ft 8 inGeometric planning model — not structural/product dimensions
Conceptual total tank height6 ftLiquid depth + freeboard
Conceptual excavation depth8 ftNot for digging; approved exterior and elevations control
Approved exterior dimensions completeNoCurrent project value

Absorption field and footprint outputs

FieldRecorded valueUse / status
Accepted field-sizing basis readyNoDependent field outputs are held
Required / derived trench-bottom areaWithheld — accepted soil or percolation basis requiredCurrent project value
Required total trench lengthWithheldCurrent project value
Equal trench countWithheldCurrent project value
Length per trenchWithheldCurrent project value
Provided total trench lengthWithheldCurrent project value
Provided trench-bottom areaWithheldCurrent project value
Primary field envelope widthWithheldCurrent project value
Primary field rectangular footprintWithheldCurrent project value
Replacement infiltrative areaWithheldCurrent project value
Primary + reserve planning footprintWithheldCurrent project value
Buffered field envelope widthWithheldCurrent project value
Buffered field envelope lengthWithheldCurrent project value

Site screening outputs

FieldRecorded valueUse / status
Calculated groundwater separationWithheld — seasonal high-water depth unknownCurrent project value
Groundwater separation checkNot determinedCurrent project value
Calculated restrictive-layer separationWithheld — restrictive-layer depth unknownCurrent project value
Restrictive-layer separation checkNot determinedCurrent project value
Slope checkPassCurrent project value
Available-area checkNot determinedCurrent project value
Rough lot area37,500 ft²Current project value
Rough building footprint2,000 ft²Current project value
Rotation-only rough field-envelope checkNot determinedDoes not prove overall fit or account for every feature/setback

Pipe, tank-internal and relative elevation outputs

FieldRecorded valueUse / status
Building sewer fall1 ftCurrent project value
Tank-to-field conveyance fall3.6 inCurrent project value
Field lateral fallWithheldCurrent project value
Outlet baffle below liquid2 ftCurrent project value
Aggregate + pipe media package depth12 inCurrent project value
Soil cover above media package1 ftCurrent project value
Field pipe center depth1 ft 4 inCurrent project value
Relative drop at tank inlet1 ftDatum: building outlet = 0
Relative drop at tank outlet1 ft 2 inDatum: building outlet = 0
Relative drop at distribution point1 ft 5.6 inDatum: building outlet = 0
Relative drop at lateral end1 ft 5.6 inDatum: building outlet = 0

Earthwork and material-order calculation outputs

FieldRecorded valueUse / status
Primary trench cut envelopeWithheldCurrent project value
Gross field media envelopeWithheldCurrent project value
Rectangular soil-cover volumeWithheldCurrent project value
Material allowance factor1.1×Current project value
Building sewer order length55 ftCurrent project value
Tank-to-field order length33 ftCurrent project value
Field lateral order lengthWithheldCurrent project value
Field pipe displacementWithheldCurrent project value
Net field aggregate volumeWithheldCurrent project value
Field aggregate order volumeWithheldCurrent project value
Pervious cover base areaWithheldCurrent project value
Pervious cover order areaWithheldCurrent project value
Triangular overfill volumeWithheldCurrent project value
Total field cover placementWithheldCurrent project value
Approved-tank excavation depthWithheld — approved exterior dimensions missingCurrent project value
Approved-tank bedding envelopeWithheld — approved exterior dimensions missingCurrent project value
Tank bedding order volumeWithheld — approved exterior dimensions missingCurrent project value
Appendix C

Readiness, warnings and release holds

Current status: Site data needed

REVIEWNo local design profile selected

The displayed allowances are editable planning values. Enter the approving authority and replace every value that differs from its current rules.

REVIEWMultifamily classification

Apartment systems commonly require an engineered distribution design, special operating approval, or treatment beyond a conventional single-home system.

NOTEDrainfield result held

Confirm that the field-sizing basis comes from the required site/soil evaluation and the approving authority to release the field result.

REVIEWApproved tank dimensions not attached

The calculated tank envelope is conceptual. Enter the selected manufacturer's approved exterior dimensions before relying on the detailed planning view for coordination.

Pre-excavation checklist status

No.RequirementRecorded status
01Local construction and operating permits approvedNot checked
02Qualified soil profile and seasonal groundwater evaluation completeNot checked
03Utilities located and excavation safety plan in placeNot checked
04Listed tank, structural rating and manufacturer instructions approvedNot checked
05Watertightness, tees, filter, risers and secure lids inspectedNot checked
06Distribution elevations and equal loading field-verifiedNot checked
07Primary and reserve areas protected from traffic and compactionNot checked
08Inspection completed before cover; as-built and maintenance plan issuedNot checked
Appendix D

Complete customer and pricing record

Draft budget estimate. Load the current takeoff to freeze design quantities before entering customer prices.

Provider and customer record

FieldRecorded valueUse / status
Business nameNot enteredCurrent project value
Business addressNot enteredCurrent project value
Business phoneNot enteredCurrent project value
Business emailNot enteredCurrent project value
License / registrationNot enteredCurrent project value
Customer nameNot enteredCurrent project value
Customer billing addressNot enteredCurrent project value
Customer phoneNot enteredCurrent project value
Customer emailNot enteredCurrent project value
Service addressNot enteredCurrent project value

Quote settings and full text

FieldRecorded valueUse / status
Quote numberSOF-001Current project value
Issue dateNot enteredCurrent project value
Valid throughNot enteredCurrent project value
Pricing modeblankDraft budget estimateAvailable choices: BlankDemoPublic-price testConfirmed custom rates
Design snapshotNot capturedCurrent fingerprint status
Scope summaryNot enteredCurrent project value
Customer noteNot enteredCurrent project value
Markup10%Current project value
Sales tax0%Tax treatment not confirmed
Markup taxableNoCurrent project value
Requested deposit30%Current project value
TermsWork begins only after approved plans and permits, utility locating, site access, material availability and signed acceptance. Payment schedule, warranty and start date are subject to the contractor’s final written agreement.Current project value
ExclusionsUnless separately priced above: engineering and survey services; soil or percolation testing; rock, groundwater, unsuitable soil or hazardous material; utility relocation; pressure-system hydraulic or electrical design; imported fill; haul-off; and authority-directed changes.Current project value

All quote lines — included, excluded and TBD

StatusItem, scope and sourceQuantityUnit rateTaxExtensionHold / verification
No quote lines have been loaded.

Quote calculation totals

Included line count
0
Priced line count
0
Included lines still TBD
0
Line-item subtotal
$0.00
Taxable line subtotal
$0.00
Overhead and profit
$0.00
Taxable markup
$0.00
Tax base
$0.00
Sales tax
$0.00
Total
$0.00
Requested deposit
$0.00
Balance after deposit
$0.00
Appendix E

Samples, assumptions and source register

URLs are printed in full so the PDF remains auditable even when links are not clickable.

No source-based sample is attached to this project.

No public-price sources are attached to the current quote.

Guidance and safety links shown by the app

  • EPA OWTS manualshttps://www.epa.gov/septic/onsite-wastewater-treatment-and-disposal-systems
  • EPA permits and siting FAQhttps://www.epa.gov/septic/frequent-questions-septic-systems
  • EPA large-capacity systemshttps://www.epa.gov/uic/large-capacity-septic-systems
  • Kansas KDHE Bulletin 4-2https://www.kdhe.ks.gov/DocumentCenter/View/8770/Bulletin-4-2-Minimum-Standards-for-Design-and-Construction-of-Onsite-Wastewater-Systems-PDF
  • Louisiana tank and field ruleshttps://ldh.la.gov/assets/oph/Center-EH/sanitarian/onsitewastewater/8145.pdf
  • Louisiana setbackshttps://ldh.la.gov/assets/oph/Center-EH/sanitarian/onsitewastewater/2896.pdf
  • Louisiana permits and inspectionshttps://ldh.la.gov/bureau-of-sanitarian-services/permit-application-information
  • OSHA excavation requirementshttps://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.651
  • Washington design ruleshttps://app.leg.wa.gov/wac/default.aspx?cite=246-272A-0230

Concept diagrams

Tank and field arrangement

Not to scale · not structural drawings

Tank planTwo-compartment concept
3,000 gal
Inlet
Primary · 67%Access
Secondary · 33%Filter
Outlet
Concept length
14.2 ft
Concept width
5.7 ft
First chamber
9.4 ft
Second chamber
4.7 ft
Tank sectionBurial and liquid envelope
manufacturer approval required
Finished grade
Freeboard
Liquid working zone
Sludge storage
Liquid depth
5 ft
Freeboard
1 ft
Soil cover
1.5 ft
Concept vertical stack
8 ft · not a dig depth
Field planSoil verification required
gravity distribution
Result intentionally withheldConfirm a qualified loading rate in section 02.
Primary footprint
Approx. field width
Line length
Reserve
100%

Preliminary takeoff

Construction materials estimate

Calculated from the current pipe runs, tank selection target and field geometry. Supplier units and final product counts still require approval.

PLANNING ESTIMATEDrainfield material quantities are withheld until the soil / percolation basis is accepted.

Not a quote, purchase order, hydraulic design, permit plan or excavation release. Verify against the approved permit plan, tank and distribution submittals, supplier units, installer takeoff and actual field conditions.

Planning allowance10%editable · continuous materials only
Building sewer pipe55 ft4 in · rounded order length
Field lateral pipeWithheldsoil / percolation basis required
Drainfield aggregateWithheldnet rectangular envelope · no supplier tonnage
Calculated geometry from current inputs; no waste addedPlanning allowance calculated base plus the disclosed allowanceSelected product count or specification comes from an approved productVerify on site route, fit or field condition controls the countWithheld required design input or approval is missing

Scroll sideways to review the full material schedule.

Planning material schedule. “Estimated amount” is rounded to the displayed order unit where a defensible continuous-material quantity is available.
CategoryMaterial / componentInstalled design quantityEstimated amountQuantity basisOrder / field note
TreatmentApproved septic tank systemNominal liquid capacity at least 3,000 gal; two-compartment planning basis3,000 gal minimum nominal capacityModel and unit count TBDSelected productSelect listed product(s); manufacturer and authority control tank count, construction, burial, loading and included accessories.
TreatmentAccess risers and secure lidsTwo compartment-access locations; entered clear opening 2 ft2 access locationsAssemblies / included accessories TBDSelected productRiser heights, seals, lid load rating and whether the tank includes them come from the approved submittal.
TreatmentInlet and outlet tee / baffle assembliesInlet +6 in / −6 in; outlet +6 in / −2 ft1 inlet + 1 outlet locationTank-integral or field-supplied · TBDSelected productVerify the approved tank package before buying separate fittings to avoid a duplicate count.
TreatmentServiceable effluent filterSelected planning option at tank outlet1 selected location1 unit or tank-included componentSelected productConfirm approval, flow rating, service clearance and whether it is included with the tank.
ConveyanceBuilding sewer pipe4 in solid pipe; class, joints and burial per approved plan50 ft entered run55 ftPlanning allowance10% added for planning; route, stock lengths, cleanouts, fittings and surveyed elevations still control the order.
ConveyanceSolid tank-to-distribution pipe4 in solid pipe; final class and joints per approved plan30 ft entered run33 ftPlanning allowance10% planning allowance; verify distribution-component location and all fittings.
DistributionGravity distribution componentLevel distribution box or other authority-approved equal-distribution detail1 planning location · outlet count withheld1 selected component · fittings TBDSelected productThe authority may require a distribution box or another approved method; product, outlet seals and elevation controls are not selected.
DrainfieldPerforated field lateral pipe4 in perforated pipe; layout withheldWithheldTBDWithheldAccepted soil / percolation basis is required before field materials are released.
DrainfieldLateral ends, inspection ports and connectionsCaps, ports, adapters, seals and flow-leveling parts per approved distribution detailTBDExact fittings and counts TBDVerify on siteProduct geometry, stock lengths, cleanout detail and approved distribution method control the takeoff.
DrainfieldApproved clean aggregate0.5 in–2.5 in entered size range; full-width rectangular media envelope less pipe displacementWithheldWithheldWithheldAccepted soil / percolation basis and field geometry are required before estimating media.
DrainfieldPermit-approved pervious cover materialPlaced over aggregate; product type, roll width, laps and edge detail require approvalWithheldWithheldWithheld10% is a planning allowance only; verify that the selected paper, fabric or other pervious barrier is accepted locally.
EarthworkSuitable pervious soil cover and overfillRectangular cover plus a transparent triangular 5 in crown approximationWithheldWithheldWithheldThis is not an imported-soil order. Reusable native soil, suitability, shrink/swell, compaction and final grading require field decisions.
EarthworkPrimary trench excavationField geometry withheldWithheldWithheldWithheldNo allowance for swell, over-excavation, unstable soil, dewatering, spoil haul-off, trench protection or contractor means and methods.
EarthworkTank bedding materialApproved tank exterior dimensions are not enteredTBDWithheldWithheldSelect the approved tank and enter its exterior dimensions before estimating bedding.
AccessoriesCleanouts, couplings, flexible boots, adapters and sealantsWatertight compatible components at each approved connection and change in directionTBD from routed plan and selected productsContractor / product takeoffVerify on siteExact count depends on pipe stock lengths, route, tank openings, distribution product and local cleanout requirements.
Site workSafety, dewatering, erosion control and restoration materialsProtective systems, pumps, barriers, stabilization, topsoil and seed as site conditions requireTBD after utility locating and field assessmentSite-specific contractor takeoffVerify on siteA competent person, permit documents and actual groundwater / soil conditions determine these materials.
Protected reserveReplacement-area materialsReserve area withheld0 installed in the current conceptNo pipe or media includedWithheldThe reserve is protected soil, not a second field material order, unless an approved phased construction plan explicitly requires it.
Excluded from automatic ordering:tank construction and reinforcing; exact riser and fitting counts; anchoring and buoyancy controls; pressure-system pumps, storage, valves, controls and electrical work; shoring, dewatering, imported fill, spoil haul-off, labor, equipment and pricing. Aggregate weight is intentionally not converted to tons without a supplier bulk density.

Customer pricing

Build a customer quotation

Freeze the current design quantities, enter your own rates, then print or save a customer-facing proposal. Blank costs stay visible as TBD.

Draft budget estimateLoad the current takeoff to freeze design quantities before entering customer prices.
No takeoff snapshotPrices not enteredTax not confirmedDesign hold remainsAll included items priced
SOF quotation

Your business name

Business address not entered
Contact details not entered
Budget estimateSOF-001Draft budget estimate
Issue date
Not entered
Valid through
Not entered
Project
Apartment wastewater concept
Design snapshot
Not captured
Prepared forCustomer name not entered
Billing address not entered
Customer contact not entered
Service addressService address not entered

Approving authority not entered

Proposed scope

Scope summary not entered.

DescriptionQtyUnitRateAmount
No included line items. Load the current takeoff or add a custom item.
All included items have a price.Displayed totals include priced items only. Excluded rows do not appear.
Line-item subtotal
$0.00
Overhead & profit (10%)
$0.00
Sales tax (0%)
$0.00
Quote total
$0.00
Requested deposit (30%)
$0.00
Balance after deposit
$0.00
Terms

Work begins only after approved plans and permits, utility locating, site access, material availability and signed acceptance. Payment schedule, warranty and start date are subject to the contractor’s final written agreement.

Exclusions

Unless separately priced above: engineering and survey services; soil or percolation testing; rock, groundwater, unsuitable soil or hazardous material; utility relocation; pressure-system hydraulic or electrical design; imported fill; haul-off; and authority-directed changes.

I authorize the listed scope and acknowledge the terms, exclusions, price and payment schedule, subject to the contractor’s final agreement.

Customer signatureDate
Contractor signatureDate
Pricing proposal only—not a permit plan, hydraulic design, excavation release or engineering approval. Final permitted scope, approved products, utility locations and field conditions control.

Field handoff

Installation parameter schedule

Verify every authority and manufacturer value before construction

ParameterCurrent conceptBasisStatus
Daily design flow1,200 gal/day8 bedrooms × allowanceLocal check
Nominal tank capacity3,000 galhydraulic retention + solids storage, rounded upApproved tank needed
Approved tank exteriorNot enteredselected product submittalManufacturer hold
Compartments2; first 67%, second 33%editable planning configurationConfirm approved tank
Access openingsAt each compartment; entered diameter 2 ftuser-entered parameterManufacturer
Pipe sizesbuilding 4 in; outlet 4 in; lateral 4 inEditable planning inputs · verify local rulesAuthority / product
Tank tees / bafflesinlet +6 in / −6 in; outlet +6 in / −2 ftcurrent liquid level; outlet 40%Authority / product
Effluent protectionOutlet tee/baffle; serviceable filter selectededitable planning conceptAuthority check
Building sewer fall1 ft over 50 ft2% entered near-tank slopeSurvey elevations
Field conveyance fall0.3 ft over 30 ft1% solid-line slopeSurvey elevations
Field lateral assembly4 in pipe at 0.2%; aggregate 6 in below / 2 in aboveseparate from solid conveyance gradeInspect before cover
DistributionLevel distribution box to equal trenchesselected conceptField verify
Primary fieldWithheldfield basis not verifiedIncomplete
Vertical separationGroundwater unknown; restrictive layer unknownentered depths minus trench bottomVerify
Rough site-plan envelopelot 150 ft × 250 ft; building 50 ft × 40 fteditable diagram assumptionsReplace with survey
Field-envelope screenAwaiting verified field basisrotation-only rectangle screen; excludes building and reserve placementNot overall fit
Setback placeholdersbuilding 5; well 50; line 5; water 50 ftuser-entered local valuesPlot on survey

Before excavation

A calculation is only one part of a safe system.

Protect the treatment soil, obtain approvals and require inspection before covering any component. Never enter a septic tank: toxic gases, oxygen deficiency and collapse can kill within minutes.